Introduction :

Shresta's solutions for power metering have helped fuel the utility industry's migration to solid state metering, while simultaneously driving down costs and improving anti-tampering capabilities. Our Solution offer the highest level of integration and flexibility in the industry and are ideal for developing low cost, intelligent utility meters for residential and industrial applications.

Shresta’s single phase meter design uses a highly integrated SOC that combines a microprocessor core, Real Time Clock (RTC), FLASH memory and LCD driver. The IC’s patent pending Single Converter Technology with a 22-bit delta-sigma ADC, 3 analog inputs, digital temperature compensation, precision voltage reference and 32-bit computation engine supports a wide range of residential metering applications with very few low cost external components.

Features :

  • Compact Size (85mm x 85mm)
  • Easy-to-use Windows Utility for calibration and testing
  • Easy programming via on board emulator Port

Specification :

Accuracy
Meter Class
1.0, 0.5, 0.2 (Optional)
Phase
Single Phase 2 Wire System
Power
Voltage Rating
240VAC (+20% and -40%)
Current Rating
Power Factor
Power Consumption
Starting Current
Frequency
Voltage Withstand
10A (Ib) – 60A (Imax)
0 to Unity (Lag & Lead)
Voltage Circuit:- 1W and 4VA
Current Circuit:- 1VA at 5A
0.2% of Ib (20mA)
50Hz +/- 5%
440VAC
Other Parameters
LEDs
  • Pulse Power
  • Reverse
  • Magnetic Tamper
  • Earth Load Tamper
LCD
Alpha Numeric LCD with Backlight (Other LCD Option)

Normal Working :

  • Active Energy

On Push button :

  • LCD check
  • Date and Time
  • Instantaneous Active Load in Watt
  • Active Cumulative Energy with Decimal Digit
  • Instantaneous Voltage (Accuracy +/- 1%)
  • Instantaneous Current (Accuracy +/- 1%)
  • Cumulative Active Energy (KWh) for each Calendar month for Previous Six Months
  • Maximum Demand (KW MD) in a Calendar month for Previous Six months with Date and Time
RS232 Port
For AMR Extension
CMR
Optical Port for Meter Reading
Anti Tamper Features
  • Reversal of Phase, Neutral or both
  • Reversal of Line and Load Terminals
  • Load through Local Earth
  • Partial Load through Earth Temper
  • Neutral Disconnect
  • AC/DC Magnetic field up to 0.2 Tesla
Event Record
Last 20 events Magnetic Tamper, if magnetic field on meter is greater than 0.2 Tesla
Other Features
Power Fail
Separate Battery with Pushbutton arrangement to read Display parameter during Power fail.
Self Diagnostics
  • RTC battery Status
  • LCD Check
Display Parameters
  • Real time & Date
  • Instantaneous voltage
  • Instantaneous Current
  • Instantaneous Active load in watt
  • Active Energy
  • Maximum Demand with Date and Time
Configuration
Windows utility / HyperTerminal
Power Requirements
Power input
5V DC
Power Consumption
Voltage Circuit : 1W and 4VA / Current Circuit:- 1VA at 5A
Mechanical
Dimension
85mm x 85mm
Environmental
Operating Temperature
0 to 55°C (32 to 131°F), 5 to 95%RH
Storage Temperature
-20 to 85°C (-4 to 185°F), 5 to 95%RH